A syringe can only be read to its smallest printed mark. For a small weekly dose from a compounded vial, the size of that mark decides how accurately you can draw it. This is why insulin syringes come in three sizes with three different graduations, and why the dose unit converter shows a rounding table instead of a single number.

The three sizes

The figures below are the common U-100 insulin syringe graduations described in the ISMP subcutaneous insulin guidance and printed on the syringes themselves. Check your own barrel; manufacturers vary.

SyringeCapacitySmallest markVolume per mark
0.3 mL (30 unit)30 units0.5 unit0.005 mL
0.5 mL (50 unit)50 units1 unit0.01 mL
1 mL (100 unit)100 units2 units0.02 mL

Some 0.3 mL syringes are marked in whole units rather than half units. If yours is, treat it as a 1-unit syringe for rounding purposes.

What rounding does to a dose

Take a prescribed 2.5 mg from a 10 mg/mL vial: 0.25 mL, exactly 25 units. Every syringe hits that exactly. Now take 1.7 mg from the same vial: 0.17 mL, 17 units. The 0.3 and 0.5 mL syringes hit it exactly. The 1 mL syringe has marks at 16 and 18; you must choose one, and either way you are 1 unit off, which at 10 mg/mL is 0.1 mg, or about 6 percent of the dose.

The percentage error shrinks as the dose grows and grows as it shrinks. At 5 units, a 1-unit rounding is a 20 percent error. This is the reason small doses belong in small syringes.

Choosing a syringe

  1. Compute the volume in units.
  2. Pick the smallest syringe whose capacity is above that volume. A syringe should not be filled to its last mark; leave headroom.
  3. Check the rounding error at that syringe's graduation. The converter's table shows it for all three.
  4. If the error is more than a few percent of the dose, ask the pharmacist whether a different concentration would put the dose on a clean mark. A 2.5 mg/mL vial turns 0.25 mg into 10 units; a 10 mg/mL vial turns it into 2.5 units, which is hard to see and hard to draw.

Doses under 2 units

Below about 2 units (0.02 mL), the meniscus, the dead space in the needle hub and the parallax of reading the barrel each become a meaningful fraction of the dose. The converter warns when a result falls in this range. The usual answer is a more dilute preparation, which the pharmacy can often supply, not a steadier hand.

Reading the barrel

Draw with the syringe vertical, needle up, and read the edge of the plunger's rubber stopper nearest the needle against the graduation, at eye level. Air bubbles displace liquid; tap them to the top and expel before reading. None of this is specific to GLP-1s, but all of it matters more when the dose is 10 units than when it is 50.

Where this does not apply

Brand pens (Wegovy, Zepbound, Mounjaro, Ozempic) meter the dose mechanically; there is no syringe and no rounding to think about. Compounded products in pre-filled syringes have already been drawn by the pharmacy. This guide is for people drawing from a vial themselves, with medication a prescriber has prescribed and a pharmacy has dispensed with instructions.